In the living community, institutions, schools, etc. are generally equipped with water pump room, its environmental humidity is often high, especially in the underground pump room, usually the relative humidity may be more than 90%, to the extent of condensation, the ground due to pump equipment and piping seepage caused by the phenomenon of stagnant water, a serious threat to the normal work of the water supply equipment in the pump room control cabinets will lead to equipment moisture rust, distribution equipment moisture short-circuit This will lead to rusting of equipment by moisture, short circuit of power distribution equipment by moisture, corrosion, and potential safety hazards.
Overcome the impact of high humidity on the underground pumping equipment, can be installed in the underground pump room in the automatic moisture dehumidifier device - dehumidifier, can automatically detect the humidity of the pump room, and automatic dehumidification, reduce the humidity of the air in the pump room, to ensure that the control cabinets in the pump room of the working environment of the optimal humidity standards.
Ensure that dehumidifiers work efficiently in underground pumping stations, generally set the humidity value of dehumidifiers to 50-60%, because the ambient humidity of about 55% is the most suitable for underground pumping station equipment and distribution equipment moisture requirements. Of course, because the region is different, the structure of the underground pump room is not the same, the humidity requirements are different, the appropriate dehumidifier configuration needs to be based on the specific environmental conditions.
Underground pump room dehumidifier needs to be placed in the air circulation, dehumidifier inlet and outlet shall not have obstacles to block, around the space should be maintained ≧ 50 cm, which is more conducive to dehumidifier air circulation, dehumidification effect will be better. When using the windows and doors are closed as far as possible, so that the indoor dehumidification effect.
As the underground pump room dehumidifier is the use of continuous circulation of air, dehumidifier air inlet equipped with air filters, dust in the air will be easy to stick in the filter, over time will clog the filter, resulting in the air inlet is not smooth, resulting in dehumidifier work efficiency is low. So must often clean the filter, depending on the specific environment, generally in the case of a cleaner environment about a month to clean.